Schweitzer Fachinformationen
Wenn es um professionelles Wissen geht, ist Schweitzer Fachinformationen wegweisend. Kunden aus Recht und Beratung sowie Unternehmen, öffentliche Verwaltungen und Bibliotheken erhalten komplette Lösungen zum Beschaffen, Verwalten und Nutzen von digitalen und gedruckten Medien.
This book highlights the mathematical aspects of treatment outcomes analysis and dose optimization in radiotherapy for heterogeneous hypoxic tumors. Hypoxia is a major factor of cancer resistance to radiotherapy treatment and is present in most tumors encountered in humans. The author tried to present a systematic consideration of radiotherapy for hypoxic tumors, but the emphasis was put on mathematical content of the problems. The book contains new approaches to the concepts of tumor control probability, equivalent uniform dose and radiotherapy dose optimization for hypoxic tumors developed by the author. Significant attention in this book is paid to comparison of models with measured and clinical data; therefore, the reduction of model parameters to overcome overfitting (model parsimony) was followed as much as possible.
Dr. Alexei Chvetsov is an Associate Professor of Clinical Medical Physics in the Department of Radiation Oncology at the University of Washington, Seattle, USA. Dr. Chvetsov received his Ph.D. in Nuclear Engineering from the Moscow Engineering Physics Institute in 1992 and completed training in radiotherapy physics at the Tom Baker Cancer Center in Canada. He is certified by the Canadian College of Physicists in Medicine since 2003 and the American Board of Radiology since 2004. His research interests include treatment response assessment, modeling and optimization of radiotherapy outcomes, inverse treatment planning and computational particle transport methods. Dr. Chvetsov is a member of Task and Work groups of the American Association of Physicists in Medicine. He also has been an Associate Editor of Medical Physics since 2011 and is currently a member of the Board of Associate Editors.
Introduction.- Tumor Models for Optimization of Radiotherapy Response.- Dose-Volume Effects in Tumor Control Probability.- Equivalent Uniform Aerobic Dose.- Dose Nonuniformity Effectiveness in Hypoxic Tumors.- Stability of Inverse Planning with Different Objective Functions.
Dateiformat: PDFKopierschutz: Wasserzeichen-DRM (Digital Rights Management)
Systemvoraussetzungen:
Das Dateiformat PDF zeigt auf jeder Hardware eine Buchseite stets identisch an. Daher ist eine PDF auch für ein komplexes Layout geeignet, wie es bei Lehr- und Fachbüchern verwendet wird (Bilder, Tabellen, Spalten, Fußnoten). Bei kleinen Displays von E-Readern oder Smartphones sind PDF leider eher nervig, weil zu viel Scrollen notwendig ist. Mit Wasserzeichen-DRM wird hier ein „weicher” Kopierschutz verwendet. Daher ist technisch zwar alles möglich – sogar eine unzulässige Weitergabe. Aber an sichtbaren und unsichtbaren Stellen wird der Käufer des E-Books als Wasserzeichen hinterlegt, sodass im Falle eines Missbrauchs die Spur zurückverfolgt werden kann.
Weitere Informationen finden Sie in unserer E-Book Hilfe.