Schweitzer Fachinformationen
Wenn es um professionelles Wissen geht, ist Schweitzer Fachinformationen wegweisend. Kunden aus Recht und Beratung sowie Unternehmen, öffentliche Verwaltungen und Bibliotheken erhalten komplette Lösungen zum Beschaffen, Verwalten und Nutzen von digitalen und gedruckten Medien.
For our discussion, electrophysiology is a general term used to describe the "electrical" characteristics of the heart. The fundamental diagnostic tools used by electrophysiologists are small catheters that are placed in the heart most commonly via the vascular system. The catheters are essentially plastic-coated wires with metal electrodes at the tip that have two functions: measurement of the electrical activity of the heart and provision of a conductive pathway to allow stimulation of the heart. Often, multiple catheters are placed in different parts of the heart, which when evaluated together can provide clues into possible mechanisms for bradycardia or tachycardia in an individual patient. Bradycardia is a far less common reason for performing an electrophysiology study and is often evaluated in the context of a patient with syncope (Chapter 26).
Most commonly, electrophysiology studies are often performed in patients with known tachycardia or patients who are at risk for tachycardia. Practical use and performance of the electrophysiology study in the evaluation of tachycardias will be the focus of all but one of the subsequent cases. Before we go through the cases, it is instructive to review the basic methods for classifying tachycardias. Clinically, tachycardias are usually classified by QRS complex width, because a narrow QRS complex suggests that the ventricles are being activated normally, while a wide QRS complex is a sign of abnormal activation of the ventricles. Although supraventricular tachycardias can be associated with profound symptoms such as shortness of breath or chest pain, they are generally not life-threatening, while a wide QRS tachycardia may signify the presence of ventricular tachycardia that can be life-threatening due to ineffective cardiac contraction. In the electrophysiology laboratory, more detailed evaluation of tachycardias is possible and, because it is often possible to treat the tachycardia by identifying and eliminating critical components, it is important to consider both anatomic location and mechanism. Unfortunately, electrophysiology can use specialized jargon or phrases that are hard to "keep straight" particularly for the novice. Some common abbreviations used in electrophysiology are defined in Table A1 in Appendix.
From a mechanistic standpoint, there are two basic types of tachycardias. The most common tachycardia mechanism is reentry. In reentry, there are two parallel pathways that are electrically separate and with different electrophysiologic properties (differences in conduction and refractoriness). An electrical impulse (generally an early beat) conducts "down" only one pathway and is able to enter the other pathway in a retrograde direction. The most well-studied example of this phenomenon are tachycardias that use an accessory pathway (Figure 1.1). In this case, the accessory pathway and the atrioventricular (AV) node provide anatomically separate connections between the atria and the ventricles. The accessory pathway and the AV node/His bundle axis are anatomically discrete, and the atria and the ventricles are electrically separated by the mitral and tricuspid annuli. Reentry can also occur in the setting of a scar that has a slowly conducting pathway through it. In this case, the slowly conducting pathway and normal tissue represent the two pathways that form the substrate for development of reentry. Traditionally, scar is described in ventricular tissue because of a myocardial infarction but could also be present in atrial tissue in the setting of atrial fibrosis from natural processes or prior ablations. It is not surprising that reentry generally is more common around "holes" in the heart, because these "holes" increase the likelihood that two separate pathways of electrical activation exist. For example, in the most common form of atrial flutter, the reentrant circuit uses a critical isthmus formed by the inferior vena cava and the tricuspid valve. The inferior vena cava and the tricuspid valve act as natural barriers that allow perpetuation of a reentrant circuit. In this case, the inferior cavotricuspid isthmus serves as one pathway, and the superior portion of the right atrium serves as the second pathway (Figure 1.2).
Figure 1.1 For most types of reentry, two separate pathways have different electrophysiologic properties, and with a carefully timed impulse, depolarization can occur in one pathway and "turn around" to depolarize the parallel pathway. The most well-described and the best clinical example of this is a patient with an accessory pathway (a). Normally, the AV node forms the only electrical connection between the atria and the ventricles, but in patients with an accessory pathway, the second electrical connection between the atria and ventricles can allow a reentrant circuit to develop. Another common scenario for reentrant arrhythmias is ventricular tachycardia in the setting of a prior myocardial infarction (b). In this case, a "patchy" myocardial scar forms an alternate pathway along with normal myocardium to activate one side of a scar to the other side of the scar.
Figure 1.2 Initiation of typical atrial flutter. (a): In sinus rhythm (*), atrial depolarization proceeds down the lateral wall of the right atrium (RA) and superiorly toward the septum. (b): With a premature atrial contraction from the left atrium (*), inferior atrial depolarization blocks in the cavotricuspid isthmus (CTI), but the wave of depolarization travels superiorly to activate the superior and lateral portions of the right atrium and enters the CTI from the other direction. (c): Slow conduction through the CTI initiates atrial flutter.
The second type of tachycardia is a focal source of rapid activation. This tachycardia mechanism is easier to conceptualize and can be thought of as outward spreading of electrical activation similar to a series of waves from repetitive drips into a pool of still water. Often, rapid activation is due to abnormal automaticity from a nest of cells, but in some cases, very small reentrant circuits can appear as focal activation. This type of reentry is often called microreentry to differentiate it from larger circuits of reentry that are called macroreentry. The actual reentrant circuit cannot be visualized unless specialized techniques are used, and often, the reentrant mechanism must be inferred by the behavior of the tachycardia. For example, termination of a tachycardia with a premature extrastimulus suggests the possibility of reentry. While reentrant circuits can be extinguished by a single early depolarization causing refractoriness, a tachycardia due to automaticity generally does not terminate, instead the usual response is transient suppression of the tachycardia.
The reason that tachycardia mechanism is so important is that it will dictate the therapeutic plan, particularly if ablation will be an option. In patients with reentry, effective ablation targets a critical pathway, isthmus, or "channel" that is essential for maintaining the tachycardia (often called "substrate"). Successful ablation is characterized by producing conduction block that can be thought of as a "dam" or a "wall" that prevents electrical current from passing. In patients with a focal source of tachycardia successful ablation targets the specific "source" of the arrhythmia.
In addition to mechanism, it is also important from an electrophysiologic standpoint to consider tachycardia using an anatomic classification. Obviously, considering the anatomic location of the tachycardia is important to effectively treat the arrhythmia with ablation. A comprehensive review of different types of tachycardia is discussed in Understanding Intracardic EGMs and ECGs (Wiley Blackwell 2010) and is beyond the scope of this case-based book. However, a cursory review at this point is reasonable. In general terms, there are only four basic anatomic locations for tachycardia (Figure 1.3).
Figure 1.3 Anatomic classification of tachycardias
(adapted with permission from Kusumoto F, Cardiovascular Pathophysiology, Harris Barton Press 1999).
Firstly, a tachycardia can arise solely within the atrium. This could be due to a stable reentrant circuit within the atrium, continuous irregular activation of the atrium (perhaps due to unstable reentrant circuits), or one or more abnormal foci of automaticity. The way to consider this is that in atrial flutter or atrial fibrillation, there is activation of the atrium somewhere all the time. In contrast, in focal or multifocal atrial tachycardias, a site(s) leads to depolarization of the atria, and the atria are quiescent until the next depolarization. Perhaps, another analogy distinguishing between reentry and automaticity is useful. Automaticity or repetitive focal firing is similar to a blinking light(s): when the light goes "off" there is no light. Reentry can be compared to the spinning earth, where as the earth spins, different areas of the earth are in the dark and "lights are turned on." In the latter case, there is always somewhere where the lights are on (the Pacific Ocean, with very few lights from ships and islands could be thought of as a region of "slow conduction"). Regardless of whether automaticity or reentry is the cause of the arrhythmia, the...
Dateiformat: ePUBKopierschutz: Adobe-DRM (Digital Rights Management)
Systemvoraussetzungen:
Das Dateiformat ePUB ist sehr gut für Romane und Sachbücher geeignet – also für „fließenden” Text ohne komplexes Layout. Bei E-Readern oder Smartphones passt sich der Zeilen- und Seitenumbruch automatisch den kleinen Displays an. Mit Adobe-DRM wird hier ein „harter” Kopierschutz verwendet. Wenn die notwendigen Voraussetzungen nicht vorliegen, können Sie das E-Book leider nicht öffnen. Daher müssen Sie bereits vor dem Download Ihre Lese-Hardware vorbereiten.Bitte beachten Sie: Wir empfehlen Ihnen unbedingt nach Installation der Lese-Software diese mit Ihrer persönlichen Adobe-ID zu autorisieren!
Weitere Informationen finden Sie in unserer E-Book Hilfe.