Schweitzer Fachinformationen
Wenn es um professionelles Wissen geht, ist Schweitzer Fachinformationen wegweisend. Kunden aus Recht und Beratung sowie Unternehmen, öffentliche Verwaltungen und Bibliotheken erhalten komplette Lösungen zum Beschaffen, Verwalten und Nutzen von digitalen und gedruckten Medien.
Practical lab manual on the stepwise description of the experimental procedures of micro electromechanical systems (MEMS) devices
Micro Electromechanical Systems (MEMS) is a highly practical lab manual on the relevant experimental procedures of MEMS devices, covering technical aspects including simulations and modeling, practical steps involved in fabrication, thorough characterizations of developed MEMS sensors, and leveraging these sensors in real-time targeted applications.
The book provides in-depth coverage of multi-physics modeling for various sensors, as well as fabrication methodologies for photolithography, soft lithography, 3D printing, and laser processing-based experimental details for the realization of MEMS devices. It also covers characterization techniques from morphological to compositional, and applications of MEMS devices in contemporary fields such as microfluidics, wearables, and energy harvesters. The text also includes a foundational introduction to the subject.
The book covers additional topics such as:
A practical guidebook on the subject, Micro Electromechanical Systems (MEMS) is a must-have resource for students, academicians, and lab technicians seeking to conduct experiments in real-time.
SANKET GOEL, PH.D., is a Professor with the Department of Electrical and Electronics Engineering and Principal Investigator with the MEMS, Microfluidics and Nanoelectronics (MMNE) Lab at BITS Pilani, Hyderabad Campus, Hyderabad, India.
About the Editor xv
List of Contributors xvii
Preface xxi
About the Companion Website xxix
1 Multiphysics Simulations on the Effect of Fluidic Concentration Profiles Over Y-Channel and T-Channel Designs 1Pavar Sai Kumar and Sanket Goel
1.1 Introduction 1
1.2 Real-Time Applications of This Study 2
1.3 Simulation Section 2
1.4 Results and Discussions 3
1.5 Conclusion 10
References 10
2 Droplet Generation in T-Junction Microchannel Using Multiphysics Software 13Abhishek Kumar and Sanket Goel
2.1 Introduction 13
2.2 Simulation Section 15
2.3 Result and Discussion 17
2.4 Conclusion 17
References 18
3 Cleanroom-Assisted and Cleanroom-Free Photolithography 21Abhishesh Pal, Satish Kumar Dubey, and Sanket Goel
3.1 Introduction 21
3.2 Photolithography Basics, Classification and Applications 22
3.3 Experimental Section on Designing and Development of Features Using Photolithography 25
3.4 Conclusion 26
References 27
4 Additive Manufacturing (3D Printing) 29Pavar Sai Kumar, Abhishek Kumar, and Sanket Goel
4.1 Stereolithography (SLA) Printing of Y-Channeled Microfluidic Chip 29
4.2 Fused Deposition Modeling (FDM): Fabrication of Single Electrode Electrochemiluminescence Device 34
References 37
5 Laser Processing 41Pavar Sai Kumar, Abhishek Kumar, Manish Bhaiyya, and Sanket Goel
5.1 CO 2 Laser for Electrochemical Sensor Fabrication 41
5.2 One-Step Production of Reduced Graphene Oxide from Paper via 450 nm Laser Ablations 45
5.3 Conclusion 50
References 50
6 Soft Lithography: DLW-Based Microfluidic Device Fabrication 53K. Ramya and Sanket Goel
6.1 Introduction 53
6.2 Designing Section 54
6.3 Conclusion 57
References 57
7 Electrode Fabrication Techniques 59Sanjeet Kumar, Abhishek Kumar, K.S. Deepak, Manish Bhaiyya, Aniket Balapure, Satish Kumar Dubey, and Sanket Goel
7.1 Inkjet Printing Technique: Electrode Fabrication for Advanced Applications 59
7.2 Screen Printing Technique for Electrochemical Sensor Fabrication 62
7.3 Physical Vapor Deposition (PVD) Technique for Electrode Fabrication 66
7.4 Conclusion 69
References 69
8 Morphological Characterization 71Dhoni Nagaraj, Yuvraj Maphrio Mao, Parvathy Nair, Sanjeet Kumar, Imran Khan, Amreen Khairunnisa, R.N. Ponnalagu, Satish Kumar Dubey, and Sanket Goel
8.1 Morphological Studies with Different Techniques 71
8.2 Scanning Electron Microscopy 71
8.3 Steps Involved in the Scanning Electron Microscope Characterization 72
8.4 X-Ray Diffraction (XRD) 74
8.5 Optical LED Microscope 79
8.6 Contact Angle 83
References 87
9 Spectroscopic Characterization 89Himanshi Awasthi, N.K. Nishchitha, Sonal Fande, and Sanket Goel
9.1 Introduction 89
9.2 Ultraviolet-Visible (UV-Vis) Spectrophotometers 90
9.3 X-Ray Photoelectron Spectroscopy (XPS) 92
9.4 Raman Spectroscopy 97
9.5 Fourier Transform Infrared (FTIR) Spectroscopy 100
References 104
10 Microfluidic Devices 105Abhishesh Pal, Pavar Sai Kumar, Sreerama Amrutha Lahari, Sonal Fande, Abhishek Kumar, Manish Bhaiyya, Sohan Dudala, R.N. Ponnalagu, Satish Kumar Dubey, and Sanket Goel
10.1 Electrochemical Detection of Bacteria, Biomarkers, Biochemical, and Environmental Pollutants 105
10.2 Microfluidics Integrated Electrochemiluminescence System for Hydrogen Peroxide Detection 114
10.3 Development of Microfluidic Chip for Colorimetric Analysis 118
10.4 Development of Disposable and Eco-Friendly µPADs as Chemiluminescence Substrates 123
10.5 Microfluidic Devices for Polymerase Chain Reaction (PCR) 128
References 131
11 Wearable Devices 135Ramya Priya Pujari, S. Vanmathi, Satish Kumar Dubey, and Sanket Goel
11.1 Application of Laser-Induced Graphene in Breath Analysis 135
11.2 Wearable Microfluidic Device for Nucleic Acid Amplification 138
11.3 Wearable Patch Biofuel Cell 142
References 145
12 Energy Devices 147Himanshi Awasthi, S. Vanmathi, and Sanket Goel
12.1 Introduction 147
12.2 Enzymatic Biofuel Cells and Microbial Fuel Cells 150
12.3 Microbial Fuel Cells (MFCs) 153
12.4 Electrochemical Characterization of Supercapacitor Energy Devices 156
References 160
13 Conclusion and Future Outlook 163Amreen Khairunnisa
Index 165
Dateiformat: PDFKopierschutz: Adobe-DRM (Digital Rights Management)
Systemvoraussetzungen:
Das Dateiformat PDF zeigt auf jeder Hardware eine Buchseite stets identisch an. Daher ist eine PDF auch für ein komplexes Layout geeignet, wie es bei Lehr- und Fachbüchern verwendet wird (Bilder, Tabellen, Spalten, Fußnoten). Bei kleinen Displays von E-Readern oder Smartphones sind PDF leider eher nervig, weil zu viel Scrollen notwendig ist. Mit Adobe-DRM wird hier ein „harter” Kopierschutz verwendet. Wenn die notwendigen Voraussetzungen nicht vorliegen, können Sie das E-Book leider nicht öffnen. Daher müssen Sie bereits vor dem Download Ihre Lese-Hardware vorbereiten.
Bitte beachten Sie: Wir empfehlen Ihnen unbedingt nach Installation der Lese-Software diese mit Ihrer persönlichen Adobe-ID zu autorisieren!
Weitere Informationen finden Sie in unserer E-Book Hilfe.