Swagata Das, PhD, is an Application Engineer (Protection) at Schweitzer Engineering Laboratories, Texas, USA. She is an IEEE Senior Member and has published in peer-reviewed journals and presented her research on fault location and fault data analysis in transmission and distribution networks to industry professionals at several IEEE Power and Energy Society conferences.
Surya Santoso, PhD, is a Professor in Electrical Engineering at The University of Texas at Austin, USA. His research interests include power systems fault analytics and protection, power systems modeling and simulation, and power quality. He is an IEEE Fellow and a Distinguished Lecturer for the IEEE Power and Energy Society.
Sundaravaradan N. Ananthan, PhD, is a Project Engineer (Protection) at Schweitzer Engineering Laboratories, Texas, USA. He has a background in power system protection and fault location in transmission and distribution networks and has published his research in many international journals and conferences.
Preface ix
About the Companion Website xi
1 Introduction 1
1.1 Power System Faults 1
1.2 What Causes Shunt Faults? 4
1.3 Aim and Importance of Fault Location 16
1.4 Types of Fault-Locating Algorithms 19
1.5 How are Fault-Locating Algorithms Implemented? 21
1.6 Evaluation of Fault-Locating Algorithms 25
1.7 The Best Fault-Locating Algorithm 26
1.8 Summary 26
2 Symmetrical Components 27
2.1 Phasors 28
2.2 Theory of Symmetrical Components 29
2.3 Interconnecting Sequence Networks 31
2.4 Sequence Impedances of Three-Phase Lines 36
2.5 Exercise Problems 41
2.6 Summary 46
3 Fault Location on Transmission Lines 49
3.1 One-Ended Impedance-Based Fault Location Algorithms 49
3.1.1 Simple Reactance Method 52
3.1.2 Takagi Method 54
3.1.3 Modified Takagi Method 56
3.1.4 Current Distribution Factor Method 57
3.2 Two-Ended Impedance-Based Fault Location Algorithms 58
3.2.1 Synchronized Method 59
3.2.2 Unsynchronized Method 60
3.2.3 Unsynchronized Negative-Sequence Method 61
3.2.4 Synchronized Line Current Differential Method 62
3.3 Three-Ended Impedance-Based Fault Location Algorithms 62
3.3.1 Synchronized Method 63
3.3.2 Unsynchronized Method 65
3.3.3 Unsynchronized Negative-Sequence Method 66
3.3.4 Synchronized Line Current Differential Method 67
3.4 Traveling-Wave Fault Location Algorithms 68
3.4.1 Single-Ended TravelingWave Method 69
3.4.2 Double-Ended Traveling-Wave Method 71
3.4.3 Error Sources 71
3.5 Exercise Problems 77
3.6 Summary 93
4 Error Sources in Impedance-Based Fault Location 95
4.1 Power System Model 95
4.2 Input Data Errors 96
4.2.1 DC Offset 97
4.2.2 CT Saturation 99
4.2.3 Aging CCVTs 101
4.2.4 Open-Delta VTs 101
4.2.5 Inaccurate Line Length 104
4.2.6 Untransposed Lines 104
4.2.7 Variation in Earth Resistivity 106
4.2.8 Non-Homogeneous Lines 107
4.2.9 Incorrect Fault Type Selection 109
4.3 Application Errors 109
4.3.1 Load 109
4.3.2 Non-Homogeneous System 111
4.3.3 Zero-Sequence Mutual Coupling 111
4.3.4 Series Compensation 118
4.3.5 Three-Terminal Lines 119
4.3.6 Radial Tap 120
4.3.7 Evolving Faults 121
4.4 Exercise Problems 122
4.5 Summary 126
5 Fault Location on Overhead Distribution Feeders 129
5.1 Impedance-Based Methods 134
5.1.1 Loop Reactance Method 135
5.1.2 Simple Reactance Method 140
5.1.3 Takagi Method 140
5.1.4 Modified Takagi Method 141
5.1.5 Girgis et al. Method 141
5.1.6 Santoso et al. Method 143
5.1.7 Novosel et al. Method 144
5.2 Challenges with Distribution Fault Location 146
5.2.1 Load 146
5.2.2 Non-Homogeneous Lines 146
5.2.3 Inaccurate Earth Resistivity 149
5.2.4 Multiple Laterals 150
5.2.5 Best Data for Fault Location: Feeder or Substation Relays 151
5.2.6 Distributed Generation 152
5.2.7 High Impedance Faults 156
5.2.8 CT Saturation 156
5.2.9 Grounding 156
5.2.10 Short Duration Faults 157
5.2.11 Missing Voltage 157
5.3 Exercise Problems 158
5.4 Summary 177
6 Distribution Fault Location With Current Only 179
6.1 Current Phasors Only Method 179
6.2 Current Magnitude Only Method 184
6.3 Short-Circuit Fault Current Profile Method 191
6.4 Exercise Problems 193
6.5 Summary 208
7 System and Operational Benefits of Fault Location 209
7.1 Verify Relay Operation 210
7.2 Discover Erroneous Relay Settings 211
7.3 Detect Instrument Transformer Installation Errors 217
7.4 Validate Zero-Sequence Line Impedance 222
7.5 Calculate Fault Resistance 225
7.6 Prove Short-Circuit Model 226
7.7 Adapt Autoreclosing in Hybrid Lines 227
7.8 Detect the Occurrence of Multiple Faults 228
7.9 Identify Impending Failures and Take Corrective Action 232
7.10 Exercise Problems 232
7.11 Summary 239
A Fault Location Suite in MATLAB 241
A.1 Understanding the Fault Location Script 241
References 261
Index 269
The power system is a complex network of generators, transformers, transmission lines, distribution feeders, loads, and other electrical components. The purpose of this network is to deliver electrical power from generators to loads through transmission lines and distribution feeders. Today, electrical power is a necessity of everyday life and is expected to be present whenever we flip the light switch, charge our phones, and turn on other gadgets. Unfortunately, this expected service may not always be available, particularly when there is a fault on the power system.
Faults are abnormal conditions on the power system that disrupt the normal flow of electrical power from generators to loads. Lightning, animal contact, tree contact, and adverse weather such as strong winds and winter storms are some of the major reasons for power system faults. Utilities take many preventive steps such as installing shield wires and surge arresters to divert the energy of lightning strikes, putting up animal guards, and trimming trees at periodic intervals to minimize the chances of a fault. In spite of all these measures, faults are inevitable on the power system. So when they occur, all efforts must be made to locate the fault as quickly as possible, make repairs, and restore power. This is why fault location is so important and critical to improving power system reliability.
We begin this chapter by explaining the types of faults that can occur on the power system and their root cause. We then move our focus to fault-locating algorithms. We discuss their aim and importance, their principles, their implementation in the field, and their evaluation criteria. Finally, we discuss how to choose the best fault-locating algorithm from among the many algorithms that have been proposed in the literature.
Faults are abnormal conditions on the power system that cause voltage, current, frequency, and power to deviate from their nominal values. Protective relays are typically used to detect and isolate these faults as quickly as possible to return the power system back to normal operating conditions. The Institute of Electrical and Electronics Engineers (IEEE) defines a protective relay as "a device whose function is to detect defective lines or apparatus or other power system conditions of an abnormal or dangerous nature and to initiate appropriate control action" [1]. Protective relays use current transformers (CTs) and potential transformers (PTs) to monitor the state of the power system. When a fault is detected, they send a trip command to circuit breakers, which then open to isolate the fault. In low-voltage distribution systems, fuses are often used instead of protective relays and circuit breakers to detect and isolate faults that create an overcurrent condition. A fuse is defined by IEEE as "an overcurrent protective device with a circuit-opening fusible part that is heated and severed by the passage of the overcurrent through it."
Faults experienced by the power system can be of two types, series faults and shunt faults. Series faults usually occur when there is an open circuit on one or two phase conductors during load conditions. Because the open circuit occurs in series with the phase conductor, these faults are known as series faults. Series faults can be caused by broken jumpers or when all three poles of a circuit breaker pole are unable to close during a manual or an automatic close operation. They can also be caused by a blown fuse. For example, Fig. 1.1 shows a distribution transformer being protected by high-side fuses. If one or two high-side fuse blows due to an overcurrent condition, it will result in a series fault. During a series fault, the current in the faulted phase decreases due to loss in load while the healthy phase continues to carry load current. The voltage and frequency of the faulted phase also increase as compared to the healthy phase. While series faults do not result in high magnitude currents to flow in the faulted phases, they make the power system unbalanced, causing unbalanced currents to flow in the power system. The heat generated by the unbalanced currents can damage transformers and motors. References [2-4] explain how protective relays can be set up to detect and isolate series faults.
Shunt faults occur when there is a shunt connection between one or more phase conductors to the ground or between each other. The shunt connection creates a short-circuit condition allowing current to flow through an alternate, lower impedance path. The lower impedance causes the current in the faulted phase to dramatically increase while the voltage of the faulted phase decreases. Because shunt faults are more common and more damaging than series faults, this book will focus on locating shunt faults.
There are four types of shunt faults (see Fig. 1.2). Single line-to-ground faults (also referred to as single phase-to-ground faults) occur when one of the three phase conductors makes contact with the ground wire or the grounded piece of an equipment. Seventy to eighty percent of all faults are single line-to-ground faults, making this the most common fault type [5]. Line-to-line faults (also referred to as phase-to-phase faults) occur when two phase conductors make contact with each other. Double line-to-ground faults (also referred to as double phase-to-ground faults) occur when two phase conductors make contact with each other and the ground wire or the grounded piece of an equipment. Three-phase faults occur when all three phase conductors make contact with each other, with or without ground connection. This fault type is quite rare and is most often the result of human errors. Three-phase faults are referred to as balanced faults as the fault involves all three phases. The other fault types involve one or two phases and make the power system unbalanced. As a result, they are referred to as unbalanced faults.
Figure 1.1 A distribution delta/wye-grounded transformer being protected by high-side fuses. A blown fuse will result in a series fault.
Figure 1.2 The four types of shunt faults.
Shunt faults can be permanent (leading to sustained outages) or temporary (leading to momentary outages). Permanent faults occur when there is permanent damage to a power system equipment and require line crew to make repairs before reenergization. Temporary faults occur due to lightning, animal contact, flying debris, and other temporary sources of fault. Such faults clear out on their own after the fault arc gets extinguished. When the arc gets extinguished by itself without the operation of any protective device, the fault is referred to as a self-clearing fault. These faults generally occur when insulation breaks down near the voltage peak but clear out on their own within a quarter cycle. The frequency of self-clearing faults increase over time and eventually lead to permanent faults [6]. Fault arcs can also get extinguished by the operation of a relay and circuit breaker. After a short open time delay, which allows the arc to get extinguished, the relay sends a reclose command to the circuit breaker to resume normal operation. Most faults on underground cables are permanent faults. In contrast, most faults on overhead systems are temporary faults [7].
Shunt faults can cause significant thermal damage to power system equipment. Thermal energy during a fault is proportional to the magnitude and duration of the fault current. If this thermal energy exceeds the thermal limit of power transformers, motors, and other power system equipment, they get damaged due to insulation failure. In addition, strong mechanical forces developed by the high magnitude current can break and physically damage power system equipment. In fact, [8] reports that transformers, a critical asset in the substation, most often fail due to mechanical and thermal stress caused by external through faults. Shunt faults are also a safety concern. Sparks from faults can start forest fires. Faults inside oil-filled transformers can lead to fires and explosions, creating dangerous working conditions for personnel inside the substation. Arc flash events in a switchgear can lead to dangerous and possibly fatal conditions due to heat, ultraviolet radiation, shrapnel, noise, and pressure from the blast [9]. Shunt faults if not cleared before the critical clearing time can make the power system unstable, leading to cascading outages [10]. Finally, shunt faults can cause voltage sags or swells on other healthy feeders. A voltage sag is defined as an event in which the rms voltage drops to a value between 0.1 and 0.9 per unit for a duration between a half cycle to one minute. An example of voltage sag during a single line-to-ground fault is shown in Fig. 1.3. Voltage sag is a power quality event that can shut down sensitive equipment in industrial plants, resulting in a revenue loss of several million dollars. Voltage swell is defined as an event in which the rms voltage increases to a value between 1.1 and 1.8 per unit for a duration between a half cycle to one minute. This can occur when single line-to-ground faults occur on an ungrounded system. Voltage of the unfaulted phases swells to 1.73 per unit and stresses the insulators. For all the reasons listed above, shunt faults must be detected and isolated as fast as possible. The latest generation of protective relays can detect faults in as fast as 2?ms [11]. The breaker takes an additional two or three cycles to open. The fast clearing time limits the...
Dateiformat: ePUBKopierschutz: Adobe-DRM (Digital Rights Management)
Systemvoraussetzungen:
Das Dateiformat ePUB ist sehr gut für Romane und Sachbücher geeignet – also für „fließenden” Text ohne komplexes Layout. Bei E-Readern oder Smartphones passt sich der Zeilen- und Seitenumbruch automatisch den kleinen Displays an. Mit Adobe-DRM wird hier ein „harter” Kopierschutz verwendet. Wenn die notwendigen Voraussetzungen nicht vorliegen, können Sie das E-Book leider nicht öffnen. Daher müssen Sie bereits vor dem Download Ihre Lese-Hardware vorbereiten.Bitte beachten Sie: Wir empfehlen Ihnen unbedingt nach Installation der Lese-Software diese mit Ihrer persönlichen Adobe-ID zu autorisieren!