- Intro
- Title Page
- Copyright
- Contents
- List of Figures
- List of Tables
- Preface
- Chapter 1. Introduction
- 1.0. Overview
- 2.0. Guide to the Manual
- Chapter 2. Station Capacity
- 1.0. Sanitary Wastewater Flow
- 1.1. Engineering Report
- 1.2. Design Life
- 1.3. Population Growth Projection
- 1.4. Land Development
- 1.5. Quantity of Available Water
- 1.6. Quantity of Wastewater Flow
- 1.7. Additional Contributors
- 1.7.1. Commercial
- 1.7.2. Industrial
- 1.7.3. Institutional
- 1.7.4. Infiltration and Inflow
- 1.8. Peak Hourly Wastewater Flowrate
- 2.0. Stormwater Flows
- 2.1. Inflow Hydrograph
- 2.2. Methods of Developing Inflow Hydrographs
- 2.2.1. Rational Method
- 2.2.2. Curve Number Method (Natural Resources Conservation Service Method)
- 2.2.2.1. Rainfall
- 2.2.2.2. Runoff Volume Parameters
- 2.2.2.3. Time Parameters
- 2.2.2.4. Determination of Runoff Volume
- 2.2.2.5. Time of Concentration, Travel Time, and Lag
- 2.2.2.6. Peak Discharge
- 2.2.3. Computerized Runoff Models
- 2.2.3.1. Planning Models
- 2.2.3.2. Design Models
- 2.2.3.3. Operational Models
- 2.2.3.4. Sensitivity Analysis
- 3.0. Combined Flow Systems
- 4.0. Flow Regulation
- 5.0. Quality of Influent
- 6.0. References
- Chapter 3. Station Configuration and Design
- 1.0. Location Considerations
- 2.0. Station Types
- 2.1. Ranges of Flow
- 2.2. Vertical Pumps
- 2.3. Submersible Pumps
- 2.4. Centrifugal Pumps
- 2.5. Horizontal Pumps
- 3.0. Wet Well Considerations
- 4.0. Aesthetic and Safety Considerations
- 5.0. Architectural Design Considerations
- 6.0. Structural Design Considerations
- 7.0. Reference
- 8.0. Suggested Readings
- Chapter 4. Pumping Systems
- 1.0. Wastewater and Stormwater Pumping Stations
- 2.0. Pumping System Hydraulics and Definitions
- 2.1. Capacity
- 2.2. Head
- 2.3. Pump Efficiency and Power Requirements
- 3.0. Pumps
- 4.0. Centrifugal Pumps
- 4.1. Pump Classification
- 4.2. Impellers
- 4.3. Pump Characteristic Curves
- 4.4. Cavitation and Net Positive Suction Head
- 4.5. Pump Operating Range
- 4.6. Affinity Laws
- 4.7. Pump Construction
- 4.7.1. Radial-Flow Volute Pumps
- 4.7.2. Axial-Flow Column Pumps
- 4.7.3. Construction Materials
- 5.0. Positive Displacement Pumps
- 5.1. Archimedes Screw Pumps
- 5.2. Pneumatic Ejectors
- 5.3. Airlift Pumps
- 5.4. Progressive Cavity Pumps
- 6.0. Force Mains
- 7.0. Wet Wells
- 8.0. Pump Drives
- 8.1. Electric Motors
- 8.2. Variable-Speed Motor Operation
- 8.2.1. Variable-Frequency Drive.
- 8.2.2. Wound-Rotor Motor Variable Speed
- 8.2.3. Variable-Voltage Motors
- 8.2.4. Variable-Speed Clutches
- 8.3. Internal Combustion Engines
- 9.0. Pump Selection
- 9.1. System Design Considerations
- 9.1.1. Flowrates
- 9.1.2. System Head-Capacity Curve
- 9.1.3. Station Location and Area Served
- 9.1.4. Force Main
- 9.2. Selection Procedure
- 9.2.1. System Head-Capacity Curve Characteristics
- 9.2.2. Preliminary Selection of Pumps
- 9.2.3. Preparation of System Curves
- 9.2.4. Analyzing System Curves
- 10.0. Examples Of Pump Selection
- 10.1. High Friction Head System
- 10.1.1. On-Off Operation of Single Speed Pumps
- 10.1.2. Two-Speed Operation of Pumps
- 10.1.3. Variable-Capacity Operation of Pumps
- 10.1.4. Power Consumption
- 10.2. High Static Head System
- 10.2.1. On-Off Operation of Constant Speed Pumps
- 10.2.2. Two-Speed Operation of Pumps
- 10.2.3. Variable-Speed Operation of Pumps
- 10.2.4. Power Consumption
- 10.3. Large Pumping Station System
- 11.0. Specifying Pump Performance
- 12.0. Reference
- 13.0. Suggested Readings
- Chapter 5. Piping Systems
- 1.0. General Design Criteria
- 1.1. Piping
- 1.2. Valves
- 1.3. Maintenance
- 1.4. Force Mains
- 2.0. Fluid Flow Fundamentals
- 2.1. System Curve
- 2.2. Equations
- 2.3. Pipe Flow Parameters
- 2.4. Pipe-Fitting Parameters
- 2.5. Station Piping
- 2.6. Discharge Line Piping
- 3.0. Water Hammer and Surge
- 3.1. Surge Pressure Limits
- 3.2. Checklist for Surge Problems
- 3.3. Rigid Water Column Theory
- 3.4. Pressure Wave Velocity
- 3.5. Negative Surge Pressure
- 3.6. Operational Changes to Reduce Water Hammer by Design
- 3.7. Surge Attenuating Devices
- 3.8. Closing Check Valve or Pump Control Valve
- 3.9. Combination Air Vent and Vacuum Break Valves
- 3.10 Pressure Surge Relief Valves
- 3.11 Surge Accumulator Tanks
- 3.12 Surge Towers
- 3.13 Bypass Check Valves
- 3.14 Pump Flywheels
- 3.15 Surge Analysis Software
- 4.0. Piping Material and Fittings
- 4.1. Pipe Joints and Connections
- 4.2. Pipe Supports for Static Loads
- 4.3. Pipe Supports for Dynamic Loads
- 5.0. Valves
- 5.1. Valve Types
- 5.2. Valve Actuation
- 5.3. Valve Applications
- 6.0. Flow Meters
- 7.0. References
- 8.0. Suggested Readings
- Chapter 6. Electrical Design
- 1.0. Reliability and Redundancy
- 2.0. Voltage Considerations
- 3.0. Substations
- 4.0. Transformers
- 5.0. Switchgear
- 6.0. Conduit and Wire
- 7.0. Lightning Protection
- 8.0. Standby Power
- 9.0. Adjustable-Speed Drives
- 9.1. Matching Variable-Frequency Drives and Motors
- 9.2. Variable-Frequency Drive Interfaces
- 9.3. Some Problems With Variable-Frequency Drives
- 10.0. Power Factor
- 11.0. Arc Flash Hazard Analysis
- 12.0. References
- 13.0. Suggested Readings
- Chapter 7. Instrumentation and Control Systems
- 1.0. Process and Instrumentation Diagrams
- 2.0. Level Measurement
- 2.1. Float Switches
- 2.2. Bubbler Systems
- 2.3. Ultrasonic Sensors
- 2.4. Radar Level Sensors
- 2.5. Submersible Level Sensors
- 3.0. Flow Measurement
- 3.1. Magnetic Flow Meters
- 3.2. Ultrasonic Flow Meters
- 3.3. Differential Producers
- 3.4. Open Channel Flow Meters-Primary Devices
- 3.5. Open Channel Flow Meters-Secondary Devices
- 3.6. Open Channel Flow Meters-Accuracy
- 3.7. Ancillary Flow Meters
- 4.0. Pressure Measurement
- 5.0. Alarms and Indication
- 5.1. Alarm
- 5.2. Equipment Status Indication
- 5.3. Process Variable Indication
- 6.0. Operator Interfaces
- 6.1. Control Panels
- 6.2. Ancillary Instrumentation
- 7.0. Control Systems
- 7.1. Conventional Control Relays
- 7.2. Programmable Logic Controllers
- 7.3. Single-Loop Digital Controllers and Other Devices
- 8.0. Control Algorithms
- 8.1. All Constant-Speed Pumps
- 8.2. All Variable-Speed Pumps
- 8.3. Combination of Constant- and Variable-Speed Pumps
- 8.4. Alternation
- 8.5. Abnormal Operating Conditions
- 9.0. Variable-Speed Drives
- 10.0. Miscellaneous
- 10.1. Installation
- 10.2. Seal Water
- 10.3. Surge Suppression
- 10.4. Contract Document Coordination
- 10.5. Training and Maintenance
- 11.0. Telemetry Systems
- 11.1. User Needs
- 11.2. System Types
- 11.3. Supervisory Control and Data Acquisition Systems
- 11.4. Communication Links
- 11.5. Remote Terminal Units
- 12.0. Reliability
- 12.1. Level Sensing Elements
- 12.2. Control Hardware and Algorithms
- 12.3. Control Power
- 12.4. Pumps and Drives
- 13.0. Testing
- 14.0. References
- 15.0. Suggested Readings
- Chapter 8. Appurtenances
- 1.0. Screening
- 1.1. Types of Screens
- 1.1.1. Trash Racks
- 1.1.2. Manually Cleaned Screens
- 1.1.3. Basket Screens
- 1.1.4. Mechanically Cleaned Screens
- 1.1.4.1. Multi-Rake, Chain-Driven Screens
- 1.1.4.2. Reciprocating Rake Screens
- 1.1.4.3. Catenary Screens
- 1.1.4.4. Continuous Self-Cleaning Screens
- 1.1.4.5. Overhead Trash Rakes
- 1.1.5. Comminutors or Grinders
- 1.2. Screenings
- 1.2.1. Quantities of Screenings
- 1.2.2. Characteristics of Screenings
- 1.2.3. Handling of Screenings
- 1.2.4. Design Practice
- 1.2.5. Installation
- 1.2.6. Design
- 1.2.7. Instrumentation
- 1.2.8. Hydraulics
- 1.2.9. Grit Removal
- 2.0. Odor Control
- 2.1. Nature and Origins of Odor
- 2.2. Odor Control Practices
- 2.2.1. Pumping Station Design and Operation
- 2.2.2. Odor Prevention
- 2.2.2.1. Flushing/Pigging
- 2.2.2.2. Air/Oxygen Injection
- 2.2.2.3. Chemical Addition
- 2.2.2.3.1. Chlorination
- 2.2.2.3.2. Hydrogen Peroxide
- 2.2.2.3.3. Potassium Permanganate
- 2.2.2.3.4. pH Adjustment
- 2.2.2.3.5. Metal Salts
- 2.2.3. Odor Treatment
- 2.2.3.1. Wet Chemical Scrubbing
- 2.2.3.2. Activated Carbon Adsorption
- 2.2.3.3. Dry Chemical Scrubbers
- 2.2.3.4. Ozone
- 2.2.3.5. Organic Media Biofilters
- 2.2.3.6. Biotrickling Filters
- 2.2.3.7. Odor Modification, Counteraction, and Masking
- 3.0. Noise Control
- 3.1. Noise Characteristics and Sources
- 3.2. Applicable Codes
- 3.3. Noise Reduction Measures
- 4.0. Building Services
- 4.1. Heating, Ventilating and Cooling
- 4.1.1. Codes and Standards
- 4.1.2. Cooling Systems
- 4.1.3. Ventilation Systems
- 4.1.4. Heating Systems
- 4.1.5. Wet Wells
- 4.1.6. Dry Wells
- 4.2. Electrical Design
- 4.3. Plumbing Design
- 4.3.1. Water Supply
- 4.3.2. Interior Sanitary Drainage
- 4.4. Site Storm Drainage
- 4.5. Utilities
- 4.5.1. Electric Utility
- 4.5.2. Telephone Utility
- 4.5.3. Gas Company
- 5.0. Other Appurtenances
- 5.1. Hoists
- 5.2. Safety Features
- 6.0. References
- 7.0. Suggested Readings
Systemvoraussetzungen
Dateiformat: ePUB
Kopierschutz: Adobe-DRM (Digital Rights Management)
Systemvoraussetzungen:
- Computer (Windows; MacOS X; Linux): Installieren Sie bereits vor dem Download die kostenlose Software Adobe Digital Editions (siehe E-Book Hilfe).
- Tablet/Smartphone (Android; iOS): Installieren Sie bereits vor dem Download die kostenlose App Adobe Digital Editions oder die App PocketBook (siehe E-Book Hilfe).
- E-Book-Reader: Bookeen, Kobo, Pocketbook, Sony, Tolino u.v.a.m. (nicht Kindle)
Das Dateiformat ePUB ist sehr gut für Romane und Sachbücher geeignet – also für „fließenden” Text ohne komplexes Layout. Bei E-Readern oder Smartphones passt sich der Zeilen- und Seitenumbruch automatisch den kleinen Displays an.
Mit Adobe-DRM wird hier ein „harter” Kopierschutz verwendet. Wenn die notwendigen Voraussetzungen nicht vorliegen, können Sie das E-Book leider nicht öffnen. Daher müssen Sie bereits vor dem Download Ihre Lese-Hardware vorbereiten.
Bitte beachten Sie: Wir empfehlen Ihnen unbedingt nach Installation der Lese-Software diese mit Ihrer persönlichen Adobe-ID zu autorisieren!
Weitere Informationen finden Sie in unserer E-Book Hilfe.