Cardiac Pacing in Clinical Practice
Springer (Publisher)
Published on 9. November 2012
Book
Paperback/Softback
XX, 461 pages
978-3-642-63741-4 (ISBN)
Description
Cardiac Pacement has undergone a rapid development in technique and application in the last years. Methods of cardiac pacement have become more successful but also more complicated. This book is written for internists in their practice and also for the specialists in cardiology to improve their therapeutic measures being informed about specific problems in cardiac pacement. Apart from the basics of cardiac pacement also indications, selection of pacers, implantation methods and complications are described. A special focus is on postoperative monitoring of the patient. A vast amount of illustrations is combined with very instructive text. This book is for daily practice and desk reference for practicioners and clinicians.
More details
Edition
Softcover reprint of the original 1st ed. 1998
Language
English
Place of publication
Berlin
Germany
Publishing group
Springer Berlin
Target group
Professional and scholarly
Professional/practitioner
Illustrations
XX, 461 p. With 2 Falttafeln.
Dimensions
Height: 235 mm
Width: 155 mm
Thickness: 27 mm
Weight
727 gr
ISBN-13
978-3-642-63741-4 (9783642637414)
DOI
10.1007/978-3-642-58810-5
Schweitzer Classification
Other editions
Additional editions

Wilhelm Fischer | Philippe Ritter
Cardiac Pacing in Clinical Practice
Book
05/1998
1st Edition
Springer
€103.74
Article exhausted; check different version
Persons
Dipl Ing. Diana Morschhäuser
Dr. med. Wilhelm Fischer
Dr. med. Michael J. Jakob
Content
Introduction: A Short History of Cardiac Pacing.- 1 Brief Review of the Anatomy, Electrophysiology and Pathophysiology of the Cardiac Conduction System.- 2 General Technical Concepts.- 3 The Pacing Modes.- 4 Indications for Permanent Pacing and Choice of Pacemaker.- 5 Implantation Techniques.- 6 Complications.- 7 Patient Follow-Up.- 8 Practical Guide to Programming.- 9 Pulse Generator and/or Lead Replacement.- 10 Conclusions.- General.- The Magnet Modes.- Medical Emergencies in Paced Patients.- Questions Asked by Paced Patients.- The Simple Questions.- Environmental Interference.- Appendix to Chapter 2.- Additional Theoretical Notions of Electricity.- Additional Facts on Stimulating the Heart.- Appendix to Chapter 3.- Special Non-Responsive SSI Mode Functions that Control the Escape Rate.- Bradycardia Diagnostic Functions.- Rate Smoothing.- Dynamic Overdrive.- Sleep Rate.- Special Non-Responsive DDD Mode Functions that Control the Escape Rate.- Automatic Search of Spontaneous QRS.- The Vitatron and Pacesetter Systems (AV Search Hysteresis, AVD Scanning).- Automatic Switching from AAI to DDD; the ELA System.- Separate Programming of the Upper P Wave Synchronous Rate and of the Maximal Sensor Rate in DDDR Pacemakers.- The Maximal Sensor Rate (MSR) is Programmed Below the Upper P Wave Synchronous Rate (UR).- The Maximal Sensor Rate Is Programmed at the Upper P Wave Synchronous Rate.- The Maximal Sensor Rate Is Programmed Above the Upper P Wave Synchronous Rate.- Protection Algorithms Against Atrial Arrhythmias.- Lower Rate Timing of the Pacemaker.- The European Pacemaker Cards and Codes 1998.- Further Reading.- Sources of Figures.- Some Internet Addresses.