
Stage 1 Design
Electrical Installation Series: Intermediate Course
Cengage Learning EMEA (Publisher)
Published on 5. October 2000
Book
Paperback/Softback
163 pages
978-1-86152-715-8 (ISBN)
Description
This study book covers the following topics on installation and Commissioning: supply, overcurrent and earth fault protection, the electrical information required, selection of conductor size, selection of cable and protective conductors, preparting for commissioning, testing, alarm systems, and fault location.
Stage 1 Design also includes a circuit design project. Circuit 1 has been completed to aid students in completing circuits 2, 3 and 4 at the relevant stages in the book. Self-assessment questions and an end test are included so that progress can be monitored.
The intermediate Course books cover the knowledge requirements for the City & Guilds of London Institute 2360 Electrical Installation Scheme, Part 2 and NVQ level 3.
Stage 1 Design also includes a circuit design project. Circuit 1 has been completed to aid students in completing circuits 2, 3 and 4 at the relevant stages in the book. Self-assessment questions and an end test are included so that progress can be monitored.
The intermediate Course books cover the knowledge requirements for the City & Guilds of London Institute 2360 Electrical Installation Scheme, Part 2 and NVQ level 3.
Reviews / Votes
Supply and Protection. Overcurrent & Earth Fault Protection. Electrical information required. Selecting the conductor size. Selecting the Cable. Selection of Protective Conductors. Preparing for Commissioning. Testing. Alarm Systems and Fault Location. End Test. Answers. Appendix.More details
Language
English
Place of publication
London
United Kingdom
Product notice
Paperback (trade)
Dimensions
Height: 297 mm
Width: 210 mm
Thickness: 9 mm
Weight
533 gr
ISBN-13
978-1-86152-715-8 (9781861527158)
Copyright in bibliographic data and cover images is held by Nielsen Book Services Limited or by the publishers or by their respective licensors: all rights reserved.
Schweitzer Classification
Persons
Malcolm Doughton, I.Eng, MIET, LCG has considerable experience in both the electrical contracting industry and further education and training. He is currently managing director of an electrical consultancy and training company
Content
About this book
Electrical Installation Series Titles
Acknowledgments
Study Guides
1 SUPPLY AND PROTECTION
Part 1
Part 2
Part 3
Part 4
2 OVERCURRENT AND EARTH FAULT PROTECTION
Part 1
Part 2
Part 3
3 ELECTRICAL INFORMATION REQUIRED
Part 1
Part
Introduction to the project
4 SELECTING THE CONDUCTOR SIZE
Part 1
Part 2
Project
5 SELECTING THE CABLE
Part 1
Project
6 SELECTION OF PROTECTIVE CONDUCTORS
Part 1
Part 2
Project
7 PREPARING FOR COMMISSIONING
Part 1
Project
8 TESTING
Part 1
Part 2
Part 3
Part 4
Part 5
Project
9 ALARM SYSTEMS AND FAULT LOCATION
Part 1
Part 2
Fault Location
End Test
Answers
Appendix
Introduction
CT Manufacturing Ltd.
Electrical Installation Series Titles
Acknowledgments
Study Guides
1 SUPPLY AND PROTECTION
Part 1
Part 2
Part 3
Part 4
2 OVERCURRENT AND EARTH FAULT PROTECTION
Part 1
Part 2
Part 3
3 ELECTRICAL INFORMATION REQUIRED
Part 1
Part
Introduction to the project
4 SELECTING THE CONDUCTOR SIZE
Part 1
Part 2
Project
5 SELECTING THE CABLE
Part 1
Project
6 SELECTION OF PROTECTIVE CONDUCTORS
Part 1
Part 2
Project
7 PREPARING FOR COMMISSIONING
Part 1
Project
8 TESTING
Part 1
Part 2
Part 3
Part 4
Part 5
Project
9 ALARM SYSTEMS AND FAULT LOCATION
Part 1
Part 2
Fault Location
End Test
Answers
Appendix
Introduction
CT Manufacturing Ltd.