Electrical Installation Calculations

For Compliance with BS 7671:2008
 
 
Wiley (Verlag)
  • 4. Auflage
  • |
  • erschienen am 11. Juli 2011
  • |
  • 202 Seiten
 
E-Book | ePUB mit Adobe DRM | Systemvoraussetzungen
978-1-119-95504-7 (ISBN)
 
Manual calculations are still extensively used and in particularare necessary for checking and verifying various softwarecalculation design packages. It is highly recommended that users ofsuch software familiarise themselves with the rudiments of thesecalculations prior to using the software packages.
This essential book fills the gap between software and manualcalculations. It provides the reader with all the necessary toolsto enable accurate calculations of circuit designs. Rather thancomplex equations, this book uses extensive worked examples to makeunderstanding the calculations simpler. The focus on workedexamples furnishes the reader with the knowledge to carry out thenecessary checks to electrical cable sizing softwareprogrammes.
Other key features include:
* Updated information on 230 volt references and voltage dropunder normal load conditions
* New sections on buried cables that take into account soilthermal conductivity, trenches and grouping, allowing readers tocarry out accurate cables sizing
* Information and examples of steel wired armour cables, new tothis edition. This includes sufficiency during short circuits and,for cables with externally run CPCs, gives unique faultconditions.
* Covers calculations of cross-sectional areas of circuit liveconductors
* Earth fault loop impedances
* Protective conductor cross-sectional areas and short circuitconditions
* Short circuit protection.
The last chapter combines all of the calculations of theprevious chapters to enable the reader to complete an accuratedesign of an installation circuit under all conditions.
A unique tool for detailed electrical installation trade,Electrical Installation Calculations, Fourth Edition isinvaluable to electricians, electrical designers, installers,technicians, contractors, and plant engineers. Senior electricalengineering students and technical colleges, junior engineers, andcontracts managers will also find this text useful.
4. Auflage
  • Englisch
John Wiley & Sons
  • 5,48 MB
978-1-119-95504-7 (9781119955047)
1119955041 (1119955041)
weitere Ausgaben werden ermittelt
About the Authors.
Preface.
Acknowledgements.
Symbols.
Definitions.
1 Calculation of the cross-sectional areas of circuit liveconductors.
General circuits.
Circuits in thermally insulating walls.
Circuits totally surrounded by thermally insulatingmaterial.
Circuits in varying external influences and installationconditions.
Circuits in ventilated trenches.
Circuits using mineral-insulated cables.
Circuits on perforated metal cable trays.
Circuits in enclosed trenches.
Circuits buried in the ground.
Grouped circuits not liable to simultaneous overload.
Circuits in low ambient temperatures.
Grouped ring circuits.
Motor circuits subject to frequent stopping and starting.
Circuits for star-delta starting of motors.
Change of parameters of already installed circuits.
Admixtures of cable sizes in enclosures.
Grouping of cables having different insulation.
2 Calculation of voltage drop under normal loadconditions.
The simple approach.
The more accurate approach taking account of conductor operatingtemperature.
The more accurate approach taking account of load powerfactor.
The more accurate approach taking account of both conductoroperating temperature and load power factor.
Voltage drop in ring circuits.
Voltage drop in ELV circuits.
3 Calculation of earth fault loop impedance.
The simple approach.
The more accurate approach taking account of conductortemperature.
Calculations taking account of transformer impedance.
Calculations concerning circuits fed from sub-distributionboards.
Calculations where conduit or trunking is used as the protectiveconductor.
Calculations where cable armouring is used as the protectiveconductor.
4 Calculations concerning protective conductorcross-sectional areas.
Calculations when the protective device is a fuse.
Calculations when an external cpc is in parallel with thearmour.
Calculations when the protective device is an mcb.
Calculations when the protective device is an RCD or RCBO.
5 Calculations related to short circuit conditions.
a. c. single-phase circuits.
The more rigorous method for A.C. single-phase circuits.
a.c. three-phase circuits.
6 Combined examples.
Appendix The touch voltage concept.
Index.

1

Calculation of the cross-sectional areas of circuit live conductors

The first stage in designing an installation after having carried out the assessment of general characteristics demanded in Part 3 of BS 7671 is the choice of the type of cable and the method of installation of that cable for each circuit. In some cases these choices are closely interrelated, e.g. non-sheathed cables are required to be enclosed in conduit, duct, ducting or trunking (Regulation 521.10.1).

Where there are several options open to the installation designer from purely technical considerations, the final choice will depend on commercial aspects or the designer’s (or client’s) personal preferences. Here it is assumed that the designer, after having taken into account the relevant external influences to which the circuit concerned is expected to be subjected, has already decided on the type of cable and the installation method to use. The appropriate table of current-carrying capacity, in Appendix 4 of BS 7671, and the appropriate column within that table are therefore known.

To determine the minimum conductor cross-sectional area of the live conductors of a particular circuit that can be tolerated the designer must:

(a) Establish what is the expected ambient temperature (ta °C). This gives the relevant value of Ca. Note that more than one value of ta°C may be encountered in some installations. Where there is more than one value the designer may opt to base all his calculations on the highest value or, alternatively, base his calculations for a particular part of the installation on the value of ta°C pertinent to that part.

(b) Decide whether the circuit is to be run singly or be bunched or grouped with other circuits and, if the latter, how many other circuits. The decision taken gives the relevant value of Cg.

(c) Decide whether the circuit is likely to be totally surrounded by thermally insulating material for any part of its length (Regulation 523.7). If the length surrounded by thermal insulation is more than 0.5 m, Ci is taken to be 0.5. For shorter lengths surroundedby thermal insulation the factors given in Table 52.2 are applied.

(d) Determine the design current (Ib) of the circuit, taking into account diversity where appropriate (Regulation 311.1), and any special characteristics of the load, e.g. motors subject to frequent stopping and starting (Regulation 552.1.1).

(e) Choose the type and nominal current rating (In) of the associated overcurrent protective device. For all cases In must be equal to or greater than Ib. Remember that overcurrent protective devices must comply with Chapter 43 of BS 7671 as regards their breaking capacity, but for the present let it be assumed the chosen devices do so comply.

(f) Establish whether it is intended the overcurrent protective device is to give:

(i) overload protection only, or

(ii) short circuit protection only, or

(iii) overload and short circuit protection.

The intended function of the overcurrent protective device not only determines whether Ib or In is used as the basis for calculating the minimum cross-sectional area of the live conductors, but also influences the value of Ca that is to be used in the calculations.

(g) Establish the maximum voltage drop that can be tolerated, (h) Estimate the route length of the circuit.

If the cable circuit is to be buried direct in the ground or in buried ducts there are further factors the designer must consider. These factors include:

(a) The thermal resistivity of the ground. The tabulated ratings given for buried cables in BS 7671 are for cables buried ‘in or around buildings’. These ratings assume that the cables are buried in dry made-up ground that is likely to contain rubble, clinker and similar materials having poor thermal properties. Because of this the ratings are based on a soil thermal resistivity of 2.5 K.m/W. This is considerably higher than the accepted value of 1.2 K.m/W for the natural soil in the UK, see BS IEC 60827–3-1. Tabulated ratings for buried cables based on a thermal resistivity of 1.2 K.m/W are given in ERA Reports 69—30 Parts III and IV as well as being provided by some UK cable suppliers. The thermal properties of the soil determine the value of Cs selected from Table 4B3 of BS 7671.

(b) The depth of burial of the cables or ducts. The deeper a circuit is buried the lower its current rating. The tabulated ratings given in BS 7671 are for a depth of burial of 0.8 m and no factors are given for different depths of burial. Derating factors for different depths, Cb, may be obtained from the cable supplier or taken from ERA Report 69—30 Part III or IV. However the ratings in many manufacturers’ data and in the ERA reports are for a depth of burial of 0.5 m. Thus the factors for different depths of burial would have to be manipulated before being applied to ratings based on a depth of 0.8 m.

(c) Ground ambient temperature. The tabulated ratings for buried cables given in BS 7671 are based on a ground ambient temperature of 20°C. This is applicable under buildings, but the designer should be aware that the accepted ground ambient temperature for general conditions in the UK is 15°C, see BS IEC 60287–3-1.

(d) Overload protection of buried cables. The requirement of Regulation 433.1.1 (iii) is applicable to circuits where the tabulated current ratings are based on an ambient temperature of 30°C. To achieve overload protection for a buried cable circuit the 1.45 factor given in Regulation 433.1.1 (iii) should be reduced to 1.3. In BS 7671 this is achieved by applying a factor of 0.9 to the current-carrying capacity, Iz, as required by Regulation 433.1.4. As an alternative the overload protective device should be selected such that I2 < 1.3Iz.

It cannot be emphasized too strongly that unless all the foregoing items are available it is not possible to design any circuit.

The general method for the determination of the minimum conductor cross-sectional areas that can be tolerated now described does not apply to cables installed in enclosed trenches. These are considered later in this chapter. The general method is as follows:

First calculate the current It where:

Table 1.1 indicates when Ix = Ib and when Ix = In. Table 1.1 also indicates from which tables in Appendix 4 of BS 7671 the appropriate values of Ca and Gg are found and it gives the values of Cd to use. For all buried cable circuits, Cc = 0.9 where the current, I2, causing effective operation of the protective device is 1.45 times the rated current, In, of the protective device. Where I2≥ 1.3 × In, Cc = 1. The value of Cs for a buried circuit is selected from Table 4B3.

Ci (when applicable) is, in the absence of more precise information, taken to be 0.5 and the calculation is then based on the tabulated current-carrying capacity for Reference Method B, i.e. for cables clipped direct to a surface and open. Note that even when the cable concerned is installed in thermal insulation for comparatively short lengths (up to 400mm), Regulation 523.7 specifies derating factors varying from 0.89 to 0.55.

Having calculated It, inspect the appropriate table of current-carrying capacity in Appendix 4 and the appropriate column in that table to find that conductor cross-sectional area having an actual tabulated current-carrying capacity (Ita) equal to or greater than the calculated It.

Note that in the following examples the circuit lengths are not given and therefore the voltage drops are not calculable. The examples are concerned solely with the determination of conductor cross-sectional areas for compliance with the requirements in BS 7671 regarding the thermal capability of cables under normal load conditions and, where appropriate, under overload conditions.

Remember that Regulation 435.1 allows the designer to assume that, if the overcurrent protective device is intended to provide both overload and short circuit protection, there is no need to carry out further calculation to verify compliance with the requirement (given in Regulation 434.5.2) regarding the latter. That assumption has been made in the following examples. When the overcurrent protective device is intended to provide short circuit protection only (e.g. in motor circuits), however, it is essential that the calculations described in Chapter 5 are made.

Table 1.1 Selection of current and of correction factors

Overcurrent protective devices are also frequently intended to provide automatic disconnection of the supply in the event of an earth fault (i.e. to provide protection against indirect contact) and the calculations that are then necessary are described in Chapter 3.

In practice, particularly with single-phase circuits which are not bunched, it will be found that voltage drop under normal load conditions determines the cross-sectional area of the circuit live conductors that can be used. For this reason Chapter 2 deals with voltage drop calculations as these are sensibly the next stage in circuit design.

General circuits

Example 1.1

A single-phase circuit is to be wired in insulated and sheathed single-core cables having copper conductors and thermoplastic insulation, 70°C. The cables are to be installed in free air, horizontal, flat spaced on cable supports (Reference Method E).

If Ib = 135 A, ta = 50°C and overload and short circuit protection is to be provided by a BS 88-2.2 ‘gG’ fuse, what is the minimum current rating for that fuse and the minimum cross-sectional area of the cable conductors that can be...

Dateiformat: EPUB
Kopierschutz: Adobe-DRM (Digital Rights Management)

Systemvoraussetzungen:

Computer (Windows; MacOS X; Linux): Installieren Sie bereits vor dem Download die kostenlose Software Adobe Digital Editions (siehe E-Book Hilfe).

Tablet/Smartphone (Android; iOS): Installieren Sie bereits vor dem Download die kostenlose App Adobe Digital Editions (siehe E-Book Hilfe).

E-Book-Reader: Bookeen, Kobo, Pocketbook, Sony, Tolino u.v.a.m. (nicht Kindle)

Das Dateiformat EPUB ist sehr gut für Romane und Sachbücher geeignet - also für "fließenden" Text ohne komplexes Layout. Bei E-Readern oder Smartphones passt sich der Zeilen- und Seitenumbruch automatisch den kleinen Displays an. Mit Adobe-DRM wird hier ein "harter" Kopierschutz verwendet. Wenn die notwendigen Voraussetzungen nicht vorliegen, können Sie das E-Book leider nicht öffnen. Daher müssen Sie bereits vor dem Download Ihre Lese-Hardware vorbereiten.

Weitere Informationen finden Sie in unserer E-Book Hilfe.


Download (sofort verfügbar)

40,99 €
inkl. 19% MwSt.
Download / Einzel-Lizenz
ePUB mit Adobe DRM
siehe Systemvoraussetzungen
E-Book bestellen

Unsere Web-Seiten verwenden Cookies. Mit der Nutzung dieser Web-Seiten erklären Sie sich damit einverstanden. Mehr Informationen finden Sie in unserem Datenschutzhinweis. Ok