3D Ultrasound in Prenatal Diagnosis

A Practical Approach
 
 
De Gruyter (Verlag)
  • 1. Auflage
  • |
  • erschienen am 12. September 2016
  • |
  • XII, 289 Seiten
 
E-Book | ePUB mit Wasserzeichen-DRM | Systemvoraussetzungen
E-Book | PDF mit Wasserzeichen-DRM | Systemvoraussetzungen
978-3-11-049735-9 (ISBN)
 
In the last decade there was a widespread use of 3D ultrasound in obstetrical imaging. It is estimated that more than half of the obstetrical clinics are currently using ultrasound equipment with 3D capabilities. Initially known for its beautiful images of the faces of babies, 3D ultrasound has, however, become an important tool in prenatal diagnosis for its ability to image fetal organs in normal and abnormal conditions. This book is a state-of-the-art work conceived as a practical guide to the application of 3D ultrasound in obstetrics. The book is illustrated with images reflecting the clinical utility of 3D ultrasound in prenatal diagnosis. The book has three sections: one section on the technical principles of 3D ultrasound, a second section on various 3D rendering tools with a step-by-step explanation of its use. The third section is dedicated to the clinical use of 3D in the examination of the fetal organs. The authors of this book have extensive expertise in 3D ultrasound that spans for more than 15 years.
  • Englisch
  • Berlin/Boston
  • |
  • Deutschland
  • Für Beruf und Forschung
  • |
  • US School Grade: College Graduate Student
  • 19,86 MB
978-3-11-049735-9 (9783110497359)
3110497352 (3110497352)
http://www.degruyter.com/isbn/9783110497359
weitere Ausgaben werden ermittelt
Rabih Chaoui, Berlin. Kai-Sven Heling, Berlin.
  • Preface
  • Contents
  • Part I: Basics of 3D Ultrasound
  • 1 Basics of 3D and 4D Volume Acquisition
  • 1.1 Introduction
  • 1.2 Preparing the volume acquisition
  • 1.3 Types of volume acquisition
  • 1.4 Conclusions
  • 2 Orientation and Navigation within a Volume
  • 2.1 Introduction
  • 2.2 Storing and exporting volume data sets
  • 2.3 Orientation in the three orthogonal planes
  • 2.4 Navigation within the orthogonal planes
  • 2.5 Artifacts in the multiplanar mode
  • 2.6 Conclusions
  • Part II: Methods of 3D Rendering
  • 3 3D Rendering of a Volume
  • 3.1 Introduction
  • 3.2 The render box and the orientation within a 3D volume
  • 3.3 Artifacts in 3D rendering
  • 3.4 Different rendering modes and the mixing of modes
  • 3.5 Special effects in 3D: dynamic depth 3D rendering and light source
  • 3.6 Threshold, transparency, brightness and color scales
  • 3.7 Magicut, the electronic scalpel
  • 3.8 Multiple light sources and "HD-live studio"
  • 3.9 Conclusions
  • 4 Volume Contrast Imaging (VCI)
  • 4.1 Introduction
  • 4.2 Principle of VCI
  • 4.3 Static VCI
  • 4.4 4D with VCI-Omniview
  • 4.5 4D with VCI-A
  • 4.6 Conclusions
  • 5 Multiplanar Display I - Orthogonal Mode and Omniview Planes
  • 5.1 Principle
  • 5.2 Multiplanar reconstruction and different ways of displaying cross-sectional images
  • 5.3 Practical approach in orthogonal mode
  • 5.4 Practical approach in getting an "anyplane" using Omniview tool
  • 5.5 Typical applications of Omniview planes
  • 5.6 Conclusions
  • 6 Multiplanar Display II: Tomographic Mode
  • 6.1 Principle
  • 6.2 Practical approach
  • 6.3 Typical applications in tomographic mode
  • 6.4 Conclusions
  • 7 Surface Mode Rendering and HD-Live
  • 7.1 Principle
  • 7.2 Practical approach
  • 7.3 Typical applications of surface mode
  • 7.4 Conclusions
  • 8 Maximum Mode Rendering
  • 8.1 Principle
  • 8.2 Practical approach
  • 8.3 Typical applications of maximum mode
  • 8.4 Conclusions
  • 9 The Minimum Mode
  • 9.1 Principle
  • 9.2 Practical approach
  • 9.3 Typical applications of minimum mode
  • 9.4 Conclusions
  • 10 The Inversion Mode
  • 10.1 Introduction
  • 10.2 Practical approach
  • 10.3 Typical applications of inversion mode
  • 10.4 Conclusions
  • 11 The Silhouette Tool
  • 11.1 Principle
  • 11.2 Practical application
  • 11.3 Typical applications of silhouette tool
  • 11.4 Conclusions
  • 12 The Glass-Body Mode and HD-Live Flow
  • 12.1 Principle
  • 12.2 Practical approach
  • 12.3 Glass-body mode with HD-live flow function
  • 12.4 Typical applications in the glass-body mode
  • 12.5 HD-live flow using the color silhouette tool
  • 12.6 Conclusions
  • 13 The B-Flow Mode
  • 13.1 Principle
  • 12.2 Practical approach
  • 13.3 Typical applications of the B-flow mode
  • 13.4 Conclusions
  • 14 Biplane Display using the Electronic Matrix Transducer
  • 14.1 Principle
  • 14.2 Practical approach
  • 14.3 Typical applications of biplane mode
  • 14.4 Conclusions
  • 15 Calculation of 3D Volumes
  • 15.1 Principle
  • 15.2 Practical approach
  • 15.3 Clinical application of volume calculation
  • 15.4 Conclusions
  • Part III: Clinical Applications of Prenatal Diagnosis
  • 16 3D Fetal Neurosonography
  • 16.1 Introduction
  • 16.2 Fetal neurosonography with 3D ultrasound
  • 16.3 3D visualization of specific brain structures
  • 16.4 Reconstruction of fetal brain structures in 3D rendering
  • 16.5 The intracranial vascular system in color Doppler
  • 16.6 Fetal neurosonography before 14 weeks of gestation
  • 16.7 Conclusions
  • 17 3D of the Fetal Skeleton
  • 17.1 Limitations in the assessment of the fetal skeleton using 2D ultrasound
  • 17.2 3D of fetal spine and ribs
  • 17.3 3D of the fetal limbs
  • 17.4 3D of the facial and cranial bones
  • 17.5 Conclusions
  • 18 3D of the Fetal Face
  • 18.1 The sonographic examination of the face in 2D and 3D ultrasound
  • 18.2 The face in multiplanar display
  • 18.3 The normal face in 3D/4D surface mode
  • 18.4 The abnormal face in 3D/4D
  • 18.5 The facial bones in 3D/4D
  • 18.6 Conclusions
  • 19 3D Intrathoracic and Intraabdominal Organs
  • 19.1 Introduction
  • 19.2 Intrathoracic organs
  • 19.3 Intraabdominal organs
  • 19.4 Conclusions
  • 20 STIC and 3D/4D Fetal Echocardiography
  • 20.1 The sonographic assessment of the heart in two-dimensional ultrasound
  • 20.2 Acquiring cardiac volumes
  • 20.3 Fetal echocardiography in 3D/4D multiplanar reconstruction
  • 20.4 Fetal heart in 3D/4D volume rendering
  • 20.5 Conclusions
  • 21 3D in Early Pregnancy
  • 21.1 Background
  • 21.2 3D volume rendering in early gestation
  • 21.3 Multiplanar display in early gestation
  • 21.4 Conclusions
  • Further literature references and sources
  • Index

Dateiformat: EPUB
Kopierschutz: Wasserzeichen-DRM (Digital Rights Management)

Systemvoraussetzungen:

Computer (Windows; MacOS X; Linux): Verwenden Sie eine Lese-Software, die das Dateiformat EPUB verarbeiten kann: z.B. Adobe Digital Editions oder FBReader - beide kostenlos (siehe E-Book Hilfe).

Tablet/Smartphone (Android; iOS): Installieren Sie bereits vor dem Download die kostenlose App Adobe Digital Editions (siehe E-Book Hilfe).

E-Book-Reader: Bookeen, Kobo, Pocketbook, Sony, Tolino u.v.a.m. (nicht Kindle)

Das Dateiformat EPUB ist sehr gut für Romane und Sachbücher geeignet - also für "fließenden" Text ohne komplexes Layout. Bei E-Readern oder Smartphones passt sich der Zeilen- und Seitenumbruch automatisch den kleinen Displays an. Mit Wasserzeichen-DRM wird hier ein "weicher" Kopierschutz verwendet. Daher ist technisch zwar alles möglich - sogar eine unzulässige Weitergabe. Aber an sichtbaren und unsichtbaren Stellen wird der Käufer des E-Books als Wasserzeichen hinterlegt, sodass im Falle eines Missbrauchs die Spur zurückverfolgt werden kann.

Weitere Informationen finden Sie in unserer E-Book Hilfe.


Dateiformat: PDF
Kopierschutz: Wasserzeichen-DRM (Digital Rights Management)

Systemvoraussetzungen:

Computer (Windows; MacOS X; Linux): Verwenden Sie zum Lesen die kostenlose Software Adobe Reader, Adobe Digital Editions oder einen anderen PDF-Viewer Ihrer Wahl (siehe E-Book Hilfe).

Tablet/Smartphone (Android; iOS): Installieren Sie die kostenlose App Adobe Digital Editions oder eine andere Lese-App für E-Books (siehe E-Book Hilfe).

E-Book-Reader: Bookeen, Kobo, Pocketbook, Sony, Tolino u.v.a.m. (nur bedingt: Kindle)

Das Dateiformat PDF zeigt auf jeder Hardware eine Buchseite stets identisch an. Daher ist eine PDF auch für ein komplexes Layout geeignet, wie es bei Lehr- und Fachbüchern verwendet wird (Bilder, Tabellen, Spalten, Fußnoten). Bei kleinen Displays von E-Readern oder Smartphones sind PDF leider eher nervig, weil zu viel Scrollen notwendig ist. Mit Wasserzeichen-DRM wird hier ein "weicher" Kopierschutz verwendet. Daher ist technisch zwar alles möglich - sogar eine unzulässige Weitergabe. Aber an sichtbaren und unsichtbaren Stellen wird der Käufer des E-Books als Wasserzeichen hinterlegt, sodass im Falle eines Missbrauchs die Spur zurückverfolgt werden kann.

Weitere Informationen finden Sie in unserer E-Book Hilfe.


Download (sofort verfügbar)

69,95 €
inkl. 19% MwSt.
Download / Einzel-Lizenz
ePUB mit Wasserzeichen-DRM
siehe Systemvoraussetzungen
PDF mit Wasserzeichen-DRM
siehe Systemvoraussetzungen
Hinweis: Die Auswahl des von Ihnen gewünschten Dateiformats und des Kopierschutzes erfolgt erst im System des E-Book Anbieters
E-Book bestellen

Unsere Web-Seiten verwenden Cookies. Mit der Nutzung des WebShops erklären Sie sich damit einverstanden. Mehr Informationen finden Sie in unserem Datenschutzhinweis. Ok